Table 1 Time constant calculations for a representative trace.

From: Aldosterone up-regulates voltage-gated potassium currents and NKCC1 protein membrane fractions

S. no

Testing voltage (mV)

Time constant (ms)

1

−40

0.223

2

−30

0.230

3

−20

0.235

4

−10

0.231

5

0

0.232

6

10

0.222

7

20

0.223

8

30

0.215

  1. Holding potential: − 90 mV.