Table 1 Estimation of the error done considering adiabatic assumption. Results obtained considering thermoviscous effects are set as reference values.

From: Numerical study of the effect of channel aspect ratio on particle focusing in acoustophoretic devices

Variable

Error

vx1

0.2494 [m s−1]

vy1

1.2560 × 10–4 [m s−1]

p1

0.3751 [MPa]

p2

81.5837 [Pa]

vx2

4.0135 × 10–4 [m s−1]

vy2

1.7834 × 10–4 [m s−1]