Table 3 Descriptive data of the necropsy room.
From: Quantification of airborne SARS-CoV-2 genomic particles in different hospital settings
Location | Date | Temperature (°C) | Humidity (%) | Total patients | E-gene (0-non-detected/1-detected) | E-gene quantification (genomic units/m3) | N-gene (0-non-detected/1-detected) |
---|---|---|---|---|---|---|---|
Autopsy room | 10/14/2020 | 17.9 | 76 | 1 | 0 | – | 0 |
10/16/2020 | 17.7 | 75 | 0 | 0 | – | 0 | |
10/19/2020 | 17.8 | 78 | 0 | 1 | 31,756 | 0 | |
10/20/2020 | 17.9 | 81 | 2 | 1 | 97,605 | 0 | |
10/21/2020 | 18.0 | 85 | 1 | 1 | 32,717 | 0 | |
10/22/2020 | 17.3 | 76 | 1 | 1 | 15,575 | 0 | |
10/23/2020 | 17.1 | 74 | 0 | 1 | 25,414 | 0 |