Table 1 Studied scenarios for drug aerosol supply to the rat capnoperitoneum phantoms (RCP).
Phantom (–) | Volume (mL) | Flow rate (SL/min) | Pressure drop (mbar) | Residence timea (s) | Purging direction (–) | Chargeb (–) |
---|---|---|---|---|---|---|
Virtual RCP | 146.2 ± 0.00 | 1.0 | n/a | 8.77 ± 0.00 | Top-down, bottom-up | n/a |
3.0 | 2.92 ± 0.00 | Top-down, bottom-up | ||||
5.0 | 1.75 ± 0.00 | Top-down, bottom-up | ||||
Physical RCP | 130.85 ± 3.89 | 1.0 | 0.08 ± 0.029 | 7.85 ± 0.24 | Top-down | +/−, + |
3.0 | 0.60 ± 0.000 | 2.62 ± 0.08 | Top-down | +/−, + | ||
5.0 | 1.72 ± 0.076 | 1.57 ± 0.05 | Top-down | +/−, + | ||
Alternative RCP | 134.65 ± 0.43 | 1.0 | 0.07 ± 0.029 | 8.08 ± 0.03 | Top-down | + |
3.0 | 0.43 ± 0.058 | 2.69 ± 0.01 | Top-down | + | ||
5.0 | 0.88 ± 0.029 | 1.62 ± 0.01 | Top-down | + |