Table 2 Gas cover rates of the nasal retina of 24-, 25-, 26- and 31-mm eye models.

From: Computational fluid dynamics (CFD) simulation analysis on retinal gas cover rates using computational eye models

 

Gas volume to the vitreous cavity (%)

100

90

80

70

60

50

40

30

20

10

0

24-mm

Supine

100

100

100

100

100

78

53

29

0

0

0

Sitting

100

100

92

68

51

43

33

26

14

4

0

Lower nasal

100

0

0

0

0

0

0

0

0

0

0

Lower temporal

100

100

100

100

100

100

100

100

100

100

0

Prone

100

100

67

33

9

0

0

0

0

0

0

Prone with closed eyes

100

91

59

11

0

0

0

0

0

0

0

25-mm

Supine

100

100

100

100

100

89

52

25

0

0

0

Sitting

100

100

78

65

54

44

30

17

8

0

0

Lower nasal

100

0

0

0

0

0

0

0

0

0

0

Lower temporal

100

100

100

100

100

100

100

100

100

100

0

Prone

100

100

72

47

14

0

0

0

0

0

0

Prone with closed eyes

100

95

62

37

0

0

0

0

0

0

0

26-mm

Supine

100

100

100

100

100

80

54

30

0

0

0

Sitting

100

100

73

62

49

39

27

16

7

0

0

Lower nasal

100

0

0

0

0

0

0

0

0

0

0

Lower temporal

100

100

100

100

100

100

100

100

100

100

0

Prone

100

100

70

47

18

0

0

0

0

0

0

Prone with closed eyes

100

92

61

34

0

0

0

0

0

0

0

31-mm

Supine

100

100

100

100

100

90

52

24

0

0

0

Sitting

100

100

73

62

49

41

31

18

8

0

0

Lower nasal

100

0

0

0

0

0

0

0

0

0

0

Lower temporal

100

100

100

100

100

100

100

100

100

100

0

Prone

100

100

68

46

15

0

0

0

0

0

0

Prone with closed eyes

100

90

63

38

0

0

0

0

0

0

0