Table 1 Fluorochrome-labeled antibodies used for flow cytometry and Western blotting.

From: Extracellular vesicles are associated with C-reactive protein in sepsis

Antigen

Source

Clone

Marker for

Fluorochrome

Abbreviation

Dilution

Supplier

Catalog number

Flow cytometry

CD14

Mouse

RMO52

Monocytes

Phycoerythrin

PE

1:10

Beckman Coulter

A07764

CD14

Mouse

RMO52

Monocytes

Allophycocyanin Alexa Fluor 750

APC AF750

1:50

Beckman Coulter

B92421

CD41

Mouse

P2

Platelets

Phycoerythrin Cyanin 7

PC7

1:20

Beckman Coulter

6607115

CD45

Mouse

J33

Leukocytes

Pacific Blue

PB

1:10

Beckman Coulter

A74763

CD235

Mouse

HIR2 (GA-R2)

Red blood cells

Allophycocyanin

APC

1:50

eBioscience

17–9987-42

CRP

Goat

Not applicable

C-reactive protein

Fluorescein Isothiocyanate

FITC

1:100

Abcam

ab34659

Annexin5

Not applicable

Not applicable

Phosphatidylserine

Phycoerythrin

PE

1:40

BD Biosciences

556421

Western blotting

CRP

Mouse

CRP-8

C-reactive protein

–

–

1:30,400

Sigma Aldrich

C1688