Table 2 Comparison table of biocompatible humidity sensors.

From: Humidity sensor based on Gallium Nitride for real time monitoring applications

Refs

Sensing material

Range (%)

Curve shape

Temperature dependency

Biocompatibility

Applications

3

Graphene oxide solution

10–90

Highly Non linear

Highly dependent

Compatible

Breathing rate and plant transpiration monitoring

52

Porous graphene/graphene oxide; graphene oxide and PEDOT;PSS; porous graphene and Ag colloids

12–97

Non linear

Independent

Compatible

Breathing rate monitoring

53

Ag-SnO2

20–80

Slightly linear

Highly dependent

Incompatible

Fish quality monitoring

54

MPOSS-PIL

11–95

Slightly linear

– (Seems dependent)

Breath monitoring

13

PEDOT:PSS, methyl red and graphene oxide in series

0–100

Approximate linear

Highly dependent

Compatible

55

MoS2 and PEDOT:PSS in series

0–80

Approximate linear

Highly dependent

Compatible

This Work

ZnO buffer layer/GaN thin film

0–100

Approximate linear

Slightly dependent

Compatible

Plant transpiration and meat quality monitoring