Table 2 Room-temperature tensile and bending test results of the Z, AS, and ZB steels.
Steel | Yield strength (MPa) | Tensile strength (MPa) | Elongation (%) | Peak-load bending angle (°) |
---|---|---|---|---|
Z | 1112 ± 4 | 1487 ± 1 | 6.1 ± 0.1 | 61.9 ± 1.13 |
AS | 1093 ± 10 | 1519 ± 3 | 6.7 ± 0.3 | 54.5 ± 0.96 |
ZB | 1201 ± 8 | 1452 ± 9 | 6.1 ± 0.2 | 72.2 ± 1.48 |