Table 2 Fitting parameters for the response characteristic according to Eqs. (2) and (3).

From: Transient behavior of compressed magnetorheological brake excited by step currents

 

0.2 A

0.4 A

0.6 A

0.8 A

1.0 A

R

F

R

F

R

F

R

F

R

F

Is (A)

0.19

0.21

0.39

0.41

0.61

0.62

0.78

0.81

0.99

1.12

Λ (ms)

11.63

11.46

11.58

11.43

11.57

11.47

11.54

11.41

11.53

11.45