Table 1 Differences in T1 measurements between methods for rest, stress, and post-contrast T1.

From: Cardiac stress T1-mapping response and extracellular volume stability of MOLLI-based T1-mapping methods

Variant

Rest T1 (ms)

(mean ± SD)

Peak Stress T1 (ms)

(mean ± SD)

Half-Dose Gd T1 (ms)

(mean ± SD)

Whole-Dose Gd T1 (ms)

(mean ± SD)

ShMOLLI

921 ± 19

979 ± 28

678 ± 41

556 ± 48

MOLLI Low HR

1001 ± 23*

1049 ± 23*$

723 ± 42*

602 ± 53*

MOLLI High HR

990 ± 23*

1027 ± 24*‡$

724 ± 39*

611 ± 48*

  1. * = P < 0.001 compared with ShMOLLI. † = P > 0.05 compared with MOLLI Low HR. ‡ = P < 0.001 compared with MOLLI Low HR. $Stress T1 data for MOLLI Low and High HR from extrapolated model-predicted dT1. Post-contrast T1 reflects the average T1 across each epoch, with statistical comparisons performed at N = 44 samples (based on the maximum number of MOLLI samples per epoch) to assure fair inter-method comparison.