Table 1 Mean values ± standard deviation (µm) of superimposition error between baseline und follow-up datasets.
From: In-vivo-wear in composite and ceramic full mouth rehabilitations over 3 years
Material | Time [year] | n | Premolar | n | Molar |
---|---|---|---|---|---|
LS2 | 1 | 46 | 6.8 ± 1.8 | 45 | 8.3 ± 1.8 |
2 | 48 | 7.5 ± 1.9 | 47 | 9.1 ± 1.7 | |
3 | 47 | 8.2 ± 2.1 | 46 | 10.9 ± 2.1 | |
COMP | 1 | 47 | 9.9 ± 2.1 | 48 | 11.7 ± 2.5 |
2 | 47 | 10.8 ± 2.1 | 39 | 12.0 ± 2.2 | |
3 | 45 | 11.9 ± 2.3 | 32 | 13.0 ± 1.7 |