Table 2 Inter-observer variability in venous and arterial flow measurements in adult and fetal vessels.

From: Structured analysis of the impact of fetal motion on phase-contrast MRI flow measurements with metric optimized gating

Adult measurements

Carotid artery

Jugular vein

Image score

0

1

2

0

1

2

Number of flow measurements

60

60

36

56

50

33

Mean flow difference in flow measurements of the observers ± SD (%)

7.1 ± 4.2

8.5 ± 5.7

39.7 ± 34.2

3.2 ± 2.6

5.8 ± 6.0

51.6 ± 55.6

ICC (95% CI)

0.99 (0.98–0.99)

0.98 (0.96–0.99)

0.81 (0.64–0.90)

0.99 (0.99–1.0)

0.99 (0.99–1.0)

0.90 (0.81–0.95)

Significance of the difference—compared to scans rated with zero

p = 0.86

p < 0.0001

p = 0.81

p < 0.0001

Fetal measurements

Artery

Vein

Image score

0

1

2

0

1

2

Number of flow measurements

3

23

12

5

7

8

Mean flow difference in flow measurements of the observers ± SD (%)

4.3 ± 4.8

5.8 ± 5.1

26.0 ± 23.4

4.2 ± 4.4

5.3 ± 3.1

28.5 ± 22.4

ICC (95% CI)

0.99 (0.78–1.0)

0.99 (0.97–0.99)

0.86 (0.51–0.96)

0.96 (0.65–0.99)

0.99 (0.94–0.99)

0.76 (− 0.20 to 0.95)

Significance of the difference—compared to scans rated with zero

p = 0.96

p = 0.03

p = 0.99

p = 0.02

  1. ICC intra class correlation, SD standard deviation, CI confidence interval.
  2. Significant values are in bold.