Table 2 Computer fit results (± error) of the impedance spectra obtained for the steel electrode that was cathodically polarized in CaCl2 brine solution containing different concentrations of copolymer 2 after 3 h.
Conc. (ppm) | Rs (Ohm cm2) | Q (µF) | n | Rct (Ohm cm2) | % Inhibition |
|---|---|---|---|---|---|
0 | 5.03 ± 0.04 | 209.3 ± 1.15 | 0.79 | 2017 ± 23.5 | – |
25 | 17.0 ± 0.14 | 60.13 ± 0.77 | 0.78 | 1577 ± 18.4 | 21.8 |
50 | 6.8 ± 0.06 | 182 ± 2.8 | 0.68 | 1276 ± 14.2 | 36.7 |
100 | 1.17 ± 0.039 | 358.2 ± 2.3 | 0.79 | 761.9 ± 11.3 | 62.3 |
150 | 29.7 ± 0.028 | 361 ± 2.2 | 0.87 | 460.3 ± 4.2 | 77.2 |
200 | 8.0 ± 0.048 | 307 ± 1.9 | 0.75 | 1285 ± 14.9 | 36.3 |