Table 3 Operating conditions for sensitivity analysis.
From: Design optimization of a magnesium-based metal hydride hydrogen energy storage system
Operating parameters | Base value | Sensitivity values |
|---|---|---|
Initial temperature of MH reactor (K) | 573 | 473, 523, 623 |
Loading pressure of hydrogen (MPa) | 1.8 | 1.2, 2.4, 3.0 |
Inlet temperature of HTF (K) | 573 | 373, 473, 673 |
Reynolds number of HTF | 14,000 | 10,000, 18,000, 22,000 |