Table 3 Operating conditions for sensitivity analysis.

From: Design optimization of a magnesium-based metal hydride hydrogen energy storage system

Operating parameters

Base value

Sensitivity values

Initial temperature of MH reactor (K)

573

473, 523, 623

Loading pressure of hydrogen (MPa)

1.8

1.2, 2.4, 3.0

Inlet temperature of HTF (K)

573

373, 473, 673

Reynolds number of HTF

14,000

10,000, 18,000, 22,000