Table 2 Ballistic impact test results for the polyimide aerogel blocks.

From: Polyimide aerogels for ballistic impact protection

Name

Areal density,

ρa (g cm−2)

Impact velocity,

vi (m −1)

Exit velocity,

ve (m s−1)

Absorbed energy,

(%)

PI-1

0.22

1283.05

1160.18

18.24

PI-2

0.19

1091.16

1018.95

12.80

PI-3

0.23

1237.40

1145.32

14.33

PI-4

0.20

466.24

369.21

37.29

PI-5

0.19

435.22

371.63

27.09

PI-6-A

0.19

160.92

0

100

PI-6-B

0.19

174.09

0

100

PI-7

0.17

179.21

31.61

96.89

PI-8

0.23

171.53

0

100

PI-9

0.18

921.65

874.03

10.07

PI-10

0.19

660.51

577.28

23.61

PI-11

0.22

875.57

819.38

12.42

PI-12

0.23

675.88

584.39

25.24

  1. Significant values are in [bold].