Table 1 The fourteen test groups are shown: Seven different stabilization techniques were tested in two different cyclic loading protocols, one with 500 N loading and one with 1000 N loading.

From: Plate osteosynthesis combined with bone cement provides the highest stability for tibial head depression fractures under high loading conditions

Group 500 N level

Osteosynthesis

Bone cement

Group 1000 N level

1

ChronOs™

8

2

2 Screws

9

3

2 Screws

ChronOs™

10

4

4 Screws

11

5

4 Screws

ChronOs™

12

6

Buttress plate

13

7

Buttress plate

ChronOs™

14