Table 1 TMR ratio and critical switching current of MTJ devices (sample1 ~ sample8) before radiation.
NO | TMR ratio | Ic (AP to P) | Ic (P to AP) |
---|---|---|---|
Sample1 | 170.8% | 216 uA | −217 uA |
Sample2 | 167.9% | 203 uA | −214 uA |
Sample3 | 159.5% | 218 uA | −233 uA |
Sample4 | 169.9% | 223 uA | −243 uA |
Sample5 | 179.1% | 175 uA | −217 uA |
Sample6 | 162.7% | 229 uA | −226 uA |
Sample7 | 174.5% | 193 uA | −222 uA |
Sample8 | 167.3% | 212 uA | −216 uA |