Table 5 Boundary settings of the glass cover.
Convective heat transfer coefficient (W/m2·K) | Free flow temperature (K) | External emissivity | External temperature (K) | Internal emissivity | ||
---|---|---|---|---|---|---|
13.68 | 276.55 | 0.94 | 276.55 | 0.85 | ||
Boundary types | Absorption rate | Transmittance | ||||
Visible light | Infrared | Hemispherical scattering coefficient | Visible light | Infrared | Hemispherical scattering coefficient | |
Translucent | 0.04 | 0.04 | 0.04 | 0.88 | 0.88 | 0.88 |