Table 2 T1 mapping—differences between diastole and systole.

From: Left ventricular T1-mapping in diastole versus systole in patients with mitral regurgitation

 

Diastole

95% Confidence interval

Lower

Upper

P Value

N

Mean ± Std deviation

Mean ± Std deviation

All

Native T1 (ms)

202

988 ± 29

985 ± 26

− 0.14

6.14

0.061

Post-contrast T1 (ms)

199

459 ± 33

462 ± 32

− 4.55

0.02

0.052

R2

411

96.0 ± 1.4

96.2 ± 1.4

− 0.34

− 0.18

< 0.001*

Males

ECV fraction (%)

129

26.5 ± 2.9

26.6 ± 2.5

− 0.42

0.20

0.489

iECV (%/m2)

129

18.9 ± 3.8

19.0 ± 3.8

− 0.30

0.14

0.482

Native T1 (ms)

131

984 ± 27

982 ± 26

− 1.61

6.15

0.251

Post-contrast T1 (ms)

128

470 ± 25

470 ± 22

− 2.64

1.63

0.640

R2

264

95.8 ± 1.4

96.1 ± 1.3

− 0.39

− 0.19

< 0.001*

Females

ECV fraction (%)

70

28.5 ± 3.0

28.4 ± 2.7

− 0.37

0.62

0.625

iECV (%/m2)

70

15.3 ± 3.8

15.3 ± 3.8

− 0.25

0.30

0.852

Native T1 (ms)

71

996 ± 32

991 ± 25

− 1.07

9.77

0.115

Post-contrast T1 (ms)

71

440 ± 38

446 ± 40

− 10.55

− 0.33

0.037*

R2

143

96.2 ± 1.3

96.4 ± 1.4

− 0.05

− 2.65

0.009*

  1. A comparison of mean T1 times and R2 values in systole and diastole of all patients and of males and females to examine difference in sexes.
  2. P values with a * denotes statistical significance.