Table 3 The summary of the parameters for constant mixing temperature cases.
From: Constant mixing temperature test of a fin-and-tube latent heat thermal energy storage
Case | Tini (°C) | Tin (°C) | Tmix (°C) | Flow (m3 hr-1) | Power (kW) | Time (min) | Heat (kWh) | SoC (1) |
---|---|---|---|---|---|---|---|---|
4 | 55 | 15 | 20 | 0.35 | 2.0 | 90 | 3.00 | 0.37 |
5 | 55 | 15 | 20 | 0.18 | 1.0 | 233 | 3.88 | 0.21 |
6 | 55 | 15 | 25 | 0.18 | 2.0 | 69 | 2.30 | 0.53 |
7 | 55 | 15 | 25 | 0.09 | 1.0 | 198 | 3.30 | 0.33 |