Table 8 Results on COVIDGR-1.0 testing with four levels of severity: P_NORMAL, P_MILD, P_MODERATE and P_SEVERE.

From: A few-shot approach for COVID-19 screening in standard and portable chest X-ray images

 

Specificity

N_Precision

N_F1

Sensitivity

P_Precision

P_F1

Accuracy

COVIDNet-CXR26

88.82 ± 0.90

3.36 ± 6.15

73.31 ± 3.79

46.82 ± 17.59

81.65 ± 6.02

56.94 ± 15.05

67.82 ± 6.11

COVID-CAPS31

65.74 ± 9.93

65.62 ± 3.98

65.15 ± 5.02

64.93 ± 9.71

66.07 ± 4.49

64.87 ± 4.92

65.34 ± 3.26

ResNet-50 without seg.19

79.87 ± 8.91

71.91 ± 3.12

75.40 ± 4.91

68.63 ± 6.08

78.75 ± 6.31

72.69 ± 3.45

74.25 ± 3.61

ResNet-50 with seg.19

78.41 ± 7.09

73.36 ± 4.66

75.46 ± 2.97

70.80 ± 8.26

77.17 ± 4.79

73.40 ± 4.01

74.60 ± 2.93

FuCiTNet50

80.79 ± 6.98

72.00 ± 4.48

75.84 ± 3.19

67.90 ± 8.58

78.48 ± 4.99

72.35 ± 4.76

74.35 ± 3.34

COVID-SDNet19

79.76 ± 6.19

74.74 ± 3.89

76.94 ± 2.82

72.59 ± 6.77

78.67 ± 4.70

75.71 ± 3.35

76.18 ± 2.70

ours (5-shot)

83.05 ± 7.60

75.22 ± 4.93

78.51 ± 2.46

71.64 ± 8.84

81.67 ± 5.70

75.73 ± 3.71

77.35 ± 2.45

ours (10-shot)

75.12 ± 6.50

85.30 ± 3.72

79.68 ± 3.88

83.96 ± 4.87

73.80 ± 4.87

78.37 ± 3.14

79.10 ± 3.41

  1. Bold values indicates the best results for each metric.