Table 1 Results of [C4mim][BF4] degradation in US-ZVZ/AC system under the different conditions.
pH | AC/ZVZ ratio | AC/ZVZ dosage | US | (Degradation rate)max within 120 min |
---|---|---|---|---|
3 | 1:1 | 0.15 g/0.15 g | 45 kHz | 93.00 |
4 | 1:1 | 0.15 g/0.15 g | 45 kHz | 67.17 |
5 | 1:1 | 0.15 g/0.15 g | 45 kHz | 69.66 |
6 | 1:1 | 0.15 g/0.15 g | 45 kHz | 60.17 |
3 | 2:1 | 0.15 g/0.075 g | 45 kHz | 49.87 |
3 | 1:1 | 0.15 g/0.15 g | 45 kHz | 93.00 |
3 | 1:2 | 0.15 g/0.3 g | 45 kHz | 90.49 |
3 | 1:1 | 0.1 g/0.1 g | 45 kHz | 87.93 |
3 | 1:1 | 0.2 g/0.2 g | 45 kHz | 91.37 |
3 | 1:1 | 0.3 g/0.3 g | 45 kHz | 93.31 |
3 | 1:1 | 0.15 g/0.15 g | 45 kHz | 93.00 |
3 | 1:1 | 0.15 g/0.15 g | 45 kHz | 93.00 |
3 | 1:1 | 0.15 g/0.15 g | Without US | 47.89 |