Table 5 Ventilation settings and target IAP for volume-controlled ventilated patients.

From: Analysing multi-perspective patient-related data during laparoscopic gynaecology procedures

Subject

Ventilation Settings

Target IAP [mmHg]

Ventilation mode

Target tidal volume \((\hbox {V}_{\textrm{T,target}})\) [ml]

Respiration rate [1/min]

Inspiration/ Expiration ratio (I:E ratio)

PEEP levels [mbar]

 

1

IMV

440 | 470

12 | 10 | 12 | 10 | 12

0.667 | 0.714

7

14

2

IMV

400 | 380

10 | 9 | 10 | 12 |14 |11

0.714

5 | 6 | 5

14

3

IMV

500 | 480

12 | 11 | 10 | 13 | 9

0.667 | 0.520

5

13

4

IMV

500

12 | 10 | 12 | 14 | 10

0.588 | 0.769 | 0.909

5

15

5

IMV

450

14 | 16

0.667

12

14

6

IMV

500 | 480 | 470 | 510 | 520 | 540 | 510 | 520 | 540 | 500

10 | 9 | 10 | 9 | 10 | 8 | 10 | 9 | 8 | 9 | 10 | 11 | 12 | 11 | 12 | 14 | 13 | 12 | 13

0.667 | 0.556 | 0.526 | 0.5 | 0.667 | 0.5 | 0.769 | 0.625 | 0.588 | 0.625 | 0.667 | 0.714 | 0.769 | 0.833 | 1.00

5

12 | 19 | 13

7

IMV

500 | 550 | 560

12 | 11 | 12

0.667

5

13 | 19 | 12

8

IMV

450 | 400 | 420

10 | 9 | 11 | 13 | 14

0.667 | 0.769

8

11 | 15

  1. IMV refers to intermittent mandatory ventilation mode (a VCV mode).