Figure 6 | Scientific Reports

Figure 6

From: Measuring electro-adhesion pressure before and after contact

Figure 6

(a) Release pressure versus adhesion pressure at 400 V for conductive and dielectric objects, and for EA patches with 6 µm and 20 µm insulator thicknesses. Each data point corresponds to one of the over 180 different EA patches tested. The data clusters for the different cases, despite the large range of electrode dimensions used in this study. Conductive objects have higher EA pressures than dielectric objects. (b) Release pressure versus adhesion pressure from 100 to 400 V for a conductive object with an EA patch insulating thickness of t = 20 µm. The data clusters show that increasing the voltage increasing both the adhesion and the release pressure.