Table 1 Parameters of each WTG.

From: Ambient data-driven SSO online monitoring of type-3 wind turbine generator integrated power systems based on MMPF-KF method

Item

Value

Item

Value

Base capacity

1.5 MVA

Mutual reactance

13.68 p.u.

Stator resistance

0.0164 p.u.

Stator reactance

0.255 p.u.

Rotor resistance

0.0183 p.u.

Rotor reactance

0.222 p.u.

T1 resistance

0.01 p.u.

T1 reactance

0.06 p.u.