Table 4 Main parameters of each part of the build system.

From: Large dynamic range stellar radiation simulation optical system

Ultra-continuum laser source main parameters

 Total power

> 8 W

 Wavelength range

430–2400 nm

 Pulse energy

> 1 µJ

 Visible power

> 1000 mW

 Power Stability

< 1%

 spot dispersion angle

< 1 mrad

DMD main parameters

 Model number

DLP6500

 Resolution

1920 × 1080

 Single pixel size

7.56 µm

 Diagonal dimension

0.65inch

 Micromirror declination

± 12°

Spectrometer main parameters

 Model number

AvaSolar 1

 Spectral range

300–1100 nm

 Spectral sampling interval

0.6 nm

 Spectral accuracy

± 0.2 nm

Parallel light tube main parameters

 Monitoring range

1000 mm

 Field of view

0.5°

 Caliber

100 mm

 Spectral range

400–1100 nm

Faint light illuminance meter main parameters

 Dynamic range

1 × 10–8–2 × 100 lx

 Uncertainty/accuracy class

Urel = 1.6%, (k = 2)