Table 4 Main parameters of each part of the build system.
From: Large dynamic range stellar radiation simulation optical system
Ultra-continuum laser source main parameters | |
Total power | > 8 W |
Wavelength range | 430–2400 nm |
Pulse energy | > 1 µJ |
Visible power | > 1000 mW |
Power Stability | < 1% |
spot dispersion angle | < 1 mrad |
DMD main parameters | |
Model number | DLP6500 |
Resolution | 1920 × 1080 |
Single pixel size | 7.56 µm |
Diagonal dimension | 0.65inch |
Micromirror declination | ± 12° |
Spectrometer main parameters | |
Model number | AvaSolar 1 |
Spectral range | 300–1100 nm |
Spectral sampling interval | 0.6 nm |
Spectral accuracy | ± 0.2 nm |
Parallel light tube main parameters | |
Monitoring range | 1000 mm |
Field of view | 0.5° |
Caliber | 100 mm |
Spectral range | 400–1100 nm |
Faint light illuminance meter main parameters | |
Dynamic range | 1 × 10–8–2 × 100 lx |
Uncertainty/accuracy class | Urel = 1.6%, (k = 2) |