Table 9 Ratios and values of overshoot, SSE, rise time, and response time of Ps and Qs in the second test case.

From: Application of fractional-order synergetic-proportional integral controller based on PSO algorithm to improve the output power of the wind turbine power system

 

Ps (W)

Qs (VAR)

 

DFOC-PI

Rise time

0.00325 s

0.0027 s

Overshoot

26,300

26,090

SSE

42,800

37,860

Response time

0.0045 s

0.005 s

Proposed technique

Rise time

0.00275 s

0.0022 s

Overshoot

37,700

9486

SSE

29,200

21,150

Response time

0.003 s

0.0045 s

Ratios

Rise time

15.38%

18.51%

Overshoot

− 30.23%

63.83%

SSE

31.77%

44.13%

Response time

33.33%

10%