Table 3 Thermoelectric Performances in Case Study.

From: Analytical study of integrating downhole thermoelectric power generation with a coaxial borehole heat exchanger in geothermal wells

Parameters

Value

Unit

Figure of merit (Z)

0.0028

K−1

Dimensionless figure of merit (ZT)

0.901

/

Total produced power

320.56

kW

Required pumping power

92.50

kW

Net electric power

228.06

kW

Thermal to electricity conversion efficiency

6.63

%