Table 6 Speckle noise performance table.
From: Research on improved black widow algorithm for medical image denoising
No | Name | MSE | PSNR | SSIM | ENL | EPI |
|---|---|---|---|---|---|---|
1 | BWOA | 0.478 | 30.250 | 0.854 | 1.542 | 0.836 |
2 | BWOA1.0 | 0.237 | 28.306 | 0.845 | 50.844 | 0.275 |
3 | BWOA2.0 | 0.428 | 25.622 | 0.725 | 1.645 | 0.872 |