Table 3 Effects of operating parameters on the separation factor for cobalt and copper ions.
Af (cm/s) | Vd (mm/s) | Vc (mm/s) | Separation factor (DCu(II)/DCo(II)) | |
---|---|---|---|---|
Cyanex272 | Cyanex272 + Cyphos IL 101 | |||
2.6 | 1.715 | 1.715 | 10.09 | 150.60 |
3 | 1.715 | 1.715 | 10.99 | 249.30 |
3.4 | 1.715 | 1.715 | 11.05 | 264.68 |
3.8 | 1.715 | 1.715 | 12.93 | 729.06 |
4.2 | 1.715 | 1.715 | 15.33 | 756.55 |
3 | 1.225 | 1.715 | 10.90 | 183.25 |
3 | 2.082 | 1.715 | 13.92 | 327.52 |
3.8 | 1.225 | 1.715 | 12.91 | 423.20 |
3.8 | 2.082 | 1.715 | 13.16 | 775.83 |
3 | 1.715 | 1.225 | 10.51 | 165.10 |
3 | 1.715 | 2.082 | 12.87 | 333.27 |
3.8 | 1.715 | 1.225 | 11.55 | 248.01 |
3.8 | 1.715 | 2.082 | 13.64 | 756.12 |