Table 1 Source term and environmental releases4.
From: RETRACTED ARTICLE: Preliminary risk assessment of in-vessel leakage accident in ITER
Maximum mass of radioactive material in the VV | Route | Maximum mass in the ST and DT | Quantity released into environment (g) | ||
---|---|---|---|---|---|
0.02 m2 in 3 FW/BLK | 0.02 m2 in 3 FW/BLK + 10DV pipes | 0.02m2 in 3 FW/BLK | 0.02 m2 in 3 FW/BLK + 10DV pipes | ||
Tritium 1000 g of HTO | VV → proST tank | 944 g | 950 g | ST-VS 0.001 | ST-VS 0.0042 |
VV → DT | 13 g | 24 g | |||
Dust 1005 kg of Tungsten | VV → ST tank | 285 kg | 303 kg | ST-VS 0.00002 | ST-VS 0.0022 |
VV → DT | 215 kg | 221 kg | |||
Activated Corrosion Products ~ 16.1 kg (in pool) and 16 g mobilizable (0.02 m2 in 3 FW/BLK) ~ 21.5 kg (in pool) and 15 g mobillisable (0.02 m2 in 3 FW/BLK + 10 DV pipes) | VV → ST | 348 g-ST | 343 g-ST | 0.0 | ST-VS ~ 10–6 |
VV → DT | 21 kg-DT | 28 kg-DT |