Table 7 The frequency and dese for each accident sequence of in-vessel leakage accident.

From: RETRACTED ARTICLE: Preliminary risk assessment of in-vessel leakage accident in ITER

Event

Radiological consequences

Frequency/Y

 

Tritium/g

Dust/g

ACP/g

Dose/Sv

In-vessel FW

pipe break

R1

2.13E−1

R2

0.016

2.8

0.019

1.293E−5

2.76E−3

R3

5.92E−3

R4

0.013

2.33

0.016

1.065E−5

2.76E−3

R5

1.56

140

0.019

9.19E−4

3.58E−4

R6

0.011

2.00

0.014

9.086E−6

1.69E−5

R7

0.011

2.00

0.014

9.086E−6

1.30E−6

R8

1.1

100

0.014

6.51E−4

2.80E−6

R9

1.32E−6

Multiple FW

pipe break

R1

9.68E−5

R2

0.038

6.77

0.046

3.103E−5

1.26E−6

R3

5.92E−5

R4

0.52

46.14

0.042

3.05E−4

1.26E−6

R5

2.707

242.88

0.033

1.595E−3

1.63E−8

R6

0.027

4.86

0.033

2.218E−5

7.67E−9

R7

0.022

4.00

0.027

1.817E−5

5.92E−10

R8

2.23

20.01

0.0256

8.579E−4

1.27E−9

R9

6.00E−10