Table 5 Areas under the receiver operating characteristic curve (AUROCs) for discrimination of preperimetric glaucoma (PPG) from normal control.
AUROC | 95% CI | P-value | ||
|---|---|---|---|---|
Lower bound | Upper bound | |||
SD-OCT average RNFL thickness | ||||
Total | 0.898 | 0.824 | 0.972 | 0.026a |
Superior | 0.846 | 0.751 | 0.941 | 0.031b |
Inferior | 0.910 | 0.841 | 0.979 | 0.019c |
SD-OCT thinner/thicker HF RNFL thickness ratio | 0.687 | 0.552 | 0.821 | 0.822d |
SD-OCT average GCIPL thickness | ||||
Total | 0.838 | 0.742 | 0.933 | 0.186a |
Superior | 0.797 | 0.688 | 0.906 | 0.190b |
Inferior | 0.806 | 0.704 | 0.909 | 0.396c |
SD-OCT thinner/thicker HF GCIPL thickness ratio | 0.834 | 0.737 | 0.931 | 0.031d |
SAP MD | 0.384 | 0.247 | 0.521 | 0.188a |
SAP PSD | 0.589 | 0.448 | 0.729 | 0.104a |
PERG N95 Amplitude | ||||
Full field | 0.738 | 0.615 | 0.861 | N/A |
Upper field | 0.744 | 0.622 | 0.866 | N/A |
Lower field | 0.689 | 0.560 | 0.819 | N/A |
PERG smaller/larger HF N95 amplitude ratio | 0.663 | 0.530 | 0.796 | N/A |
PERG P50 Amplitude | ||||
Full field | 0.680 | 0.546 | 0.814 | 0.103a |
Upper field | 0.619 | 0.481 | 0.756 | 0.202c |
Lower field | 0.582 | 0.439 | 0.726 | 0.033b |
PERG smaller/larger HF P50 amplitude ratio | 0.534 | 0.391 | 0.677 | 0.175d |