Table 4 Pharmacodynamics parameters of etomidate for the test and reference formulations after a single dose of etomidate through the intravenous infusion pump in healthy subjects (n = 51).
Pharmacodynamics parameters | Test | Reference |
---|---|---|
t-BISmin (min) | 22.0 (3.0, 59.0) | 22.0 (1.0, 58.0) |
BISmin | 72.2 ± 16.57 | 69.5 ± 13.82 |
BISAUC0–60min | 5396.94 ± 251.696 | 5383.30 ± 220.033 |