Table 1 Applied parameters for the development of polymer membrane fuel stack.
From: Design of adaptive hybrid MPPT controllers with universal input voltage DC–DC converter for RES’s
Variables of the fuel stack | Values |
|---|---|
Peak power appears across the polymer fuel stack (PMPP) | 6 kW |
Peak voltage appears across the polymer fuel stack (VMPP) | 45.00 V |
Peak current appears across the polymer fuel stack (IMPP) | 133.331 A |
Voltage appeared in the fuel network at open-circuited (VOC) | 64.989 V |
Inside the fuel network, the available oxygen pressure parameter | 1.189 bar |
Inside the fuel network, the available hydrogen pressure parameter | 1.822 bar |
Overall fuel cells used for the design of fuel network (N) | 65 |
Inside the fuel network, the general rate of airflow (Ipm) | 508.889 |
Natural gas constant available in the fuel network (R) | 85.22189 [J mol−1 K−1] |
Faraday value of the fuel network for various water membranes (F) | 93,500.1843 [C mol−1] |
Overall network chemical oxidization rate value | 22.027% |
Overall network chemical fuel oxidization rate value | 98.667% |
Overall hydrogen quantity applied to the system | 98.92% |
In the fuel network, the effective O2 utilization percentage value | 61.782% |