Figure 11
From: Stabilized voltage source inverter for sensitive loads in nuclear installations

The sinusoidal voltage measured by Tektronix oscilloscope model TDS 2012B at the output of the SSF of the proposed inverter for load impedance \({Z}_{L}=55\Omega\) with periodic time \(T=0.02 \, \text{s}\) and duty cycle \(D=1\); the SSF parameters are \({C}_{F}=750 \, \upmu \text{F}\), \({L}_{F}=13.5 \, \text{mH}\), and \({r}_{F}=3.1 \, \text{m}\Omega\). (a) Time-waveform of the SSF output voltage. (b) The corresponding normalized spectrum magnitude, \(\left|{V}_{O}\left(f\right)\right|\), obtained by the built-in FFT option of the oscilloscope.