Table 3 Comparison of various energy aspects with proposed work.
From: Connected smart elevator systems for smart power and time saving
Elevator energy aspects | High-rise building | Low-rise building | ||||
---|---|---|---|---|---|---|
Residential apartments (HA) | Commercial office (HO) | Proposed work | Residential apartment (LA) | Commercial office (LO) | Proposed work | |
No. of trips per day | 340 | 504 | 388 | 176 | 589 | 351 |
Running power, Pr (W) | 13,000 | 13,000 | 10,000 | 4900 | 8500 | 3082 |
Standby power 5 min, Pst5(W) | 252.6 | 252.6 | 252.6 | 190.25 | 120.1 | 145.7 |
Non-running power, Pnr (W) | 1749.1 | 1749.1 | 1499.1 | 1645 | 409.8 | 821.9 |
Daily energy consumption (kWh) | 49.81 | 52.52 | 39.39 | 5.53 | 29.68 | 14.08 |
Annual energy consumption (kWh) | 14,485 | 13,617.6 | 10,819.5 | 1656.48 | 6422.88 | 3039.68 |