Table 3 Fitted electrochemical parameters deduced from EIS tests for Carbon steel in H2S and 1M HCl co-existing solution without and with different concentrations of BMT at 293K.

From: Insights into the newly synthesized bi- Mannich base for carbon steel corrosion inhibition in H2S and HCl solution

Concentration (ppm)

EOCP (V)

Phase angle maxima (deg)

Rs

Y1

n1

Rf

Y2

n2

Rct

Rp

η%

0

 − 0.45472

27.89

4.34

/

/

/

385.9

0.877

9.7

9.7

0.3

 − 0.44305

56.96

2.909

126.7

0.902

9.4

192.6

0.772

99.4

108.8

91.1

0.6

 − 0.44066

58.11

2.76

107.5

0.931

11.1

266.7

0.748

102.2

113.3

91.4

0.9

 − 0.43087

60.00

2.51

115.4

0.927

17.1

234.1

0.735

109.2

249.9

96.1

3.0

 − 0.40837

64.05

2.367

166.6

0.861

23.8

210.4

0.520

277.4

370.0

97.3

6.0

 − 0.40482

65.93

2.413

131.4

0.879

25.5

542.9

0.313

401.8

427.3

97.7

9.0

 − 0.40397

67.18

2.519

119.6

0.857

18.6

400.2

0.229

488.2

490.1

98.0