Table 8 Relative error after updating for the sensitivity method.

From: Modal test and finite element updating of sprayer boom truss

Order

Experimental modal frequency /(Hz)

Experimental modal frequency /(Hz)

Relative error (%)

First-order modalities

27.394

28.312

3.35

Second-order modalities

41.518

43.578

4.961

Third-order modalities

60.436

60.64

0.338

Fourth-order modalities

69.317

65.925

4.893

Fifth-order modality

107.088

104.757

2.177

Sixth-order modalities

115.704

111.826

3.352