Table 1 Candidate \((n,\gamma )\) reactions measured in this work.

From: Epithermal neutron activation dosimetry–(n, γ) reactions under boron-based filters

Nuclear reaction

\(E_{50\%}\) under \(\hbox {B}\hbox {N}\), 4 mm [MeV]

Product half-life (Nudat-2.7)

\(^{26}\)Mg(n,\(\gamma\))\(^{27}\)Mg

0.2165

9.458 min

\(^{82}\)Se(n,\(\gamma\))\(^{83}\)Se

0.09615

22.25 min

\(^{140}\)Ce(n,\(\gamma\))\(^{141}\)Ce

0.02666

32.511 d

\(^{94}\)Zr(n,\(\gamma\))\(^{95}\)Zr

0.01722

64.032 d

\(^{64}\)Ni(n,\(\gamma\))\(^{65}\)Ni

\(9.30 \times 10^{-3}\)

2.5175 h

\(^{74}\)Ge(n,\(\gamma\))\(^{75}\)Ge

\(7.34 \times 10^{-3}\)

82.78 min

\(^{27}\)Al(n,\(\gamma\))\(^{28}\)Al

\(5.81 \times 10^{-3}\)

2.245 min

\(^{130}\)Te(n,\(\gamma\))\(^{131}\)Te

\(5.75 \times 10^{-3}\)

25.0 min

\(^{64}\)Zn(n,\(\gamma\))\(^{65}\)Zn

\(2.83 \times 10^{-3}\)

243.93 d

\(^{23}\)Na(n,\(\gamma\))\(^{24}\)Na

\(2.40 \times 10^{-3}\)

14.997 h