Table 3 Classification reports of ConvNeXt-X models on ECG data.

From: A hybrid cardiovascular arrhythmia disease detection using ConvNeXt-X models on electrocardiogram signals

Exp. no.

DB tech.

Model

Class

Precision

Recall

F1-score

1

RO

ConvNeXtBase

Normal

99.79

99.61

99.7

Fusion of paced and normal

99.72

99.62

99.67

Premature ventricular contraction

99.51

99.63

99.57

Atrial premature

99.57

99.66

99.62

Fusion of ventricular and normal

99.66

99.73

99.69

ConvNeXtSmall

Normal

99.78

99.69

99.73

Fusion of paced and normal

99.73

99.64

99.68

Premature ventricular contraction

99.54

99.66

99.6

Atrial premature

99.65

99.64

99.65

Fusion of ventricular and normal

99.65

99.72

99.68

ConvNeXtTiny

Normal

99.83

99.75

99.79

Fusion of paced and normal

99.77

99.71

99.74

Premature ventricular contraction

99.59

99.68

99.63

Atrial premature

99.72

99.68

99.7

Fusion of ventricular and normal

99.68

99.78

99.73

2

STL

ConvNeXtBase

Normal

99.82

99.66

99.74

Fusion of paced and normal

99.76

99.66

99.71

Premature ventricular contraction

99.52

99.68

99.6

Atrial premature

99.61

99.67

99.64

Fusion of ventricular and normal

99.72

99.76

99.74

ConvNeXtSmall

Normal

99.82

99.73

99.78

Fusion of paced and normal

99.78

99.7

99.74

Premature ventricular contraction

99.57

99.7

99.63

Atrial premature

99.7

99.71

99.7

Fusion of ventricular and normal

99.73

99.76

99.74

ConvNeXtTiny

Normal

99.88

99.77

99.82

Fusion of paced and normal

99.79

99.73

99.76

Premature ventricular contraction

99.62

99.72

99.67

Atrial premature

99.76

99.73

99.75

Fusion of ventricular and normal

99.72

99.82

99.77