Table 2 CCD plan of factors and the results of two obtained responses.
Run no. | Symbol code: factors (unit) | Responses (unit) | |||
|---|---|---|---|---|---|
Sulfur dosage (SD) (g/l) | Inoculum size (v/v) | Initial pH | Sulfate concentration (SC) (g/l) | ΔpH | |
1 | 10 | 6 | 2 | 24.3 | 1 |
2 | 10 | 10 | 2 | 25.0 | 1.25 |
3 | 12.5 | 8 | 2.5 | 30.1 | 1.60 |
4 | 15 | 6 | 2 | 37.4 | 1.15 |
5 | 5 | 6 | 2 | 11.6 | 0.9 |
6 | 10 | 6 | 2 | 24.4 | 0.9 |
7 | 12.5 | 4 | 2.5 | 31.9 | 1.55 |
8 | 10 | 6 | 2 | 24.3 | 1 |
9 | 10 | 6 | 3 | 24.3 | 1.88 |
10 | 7.5 | 4 | 1.5 | 17.6 | 0.68 |
11 | 7.5 | 8 | 1.5 | 18.9 | 0.74 |
12 | 10 | 6 | 2 | 24 | 0.94 |
13 | 10 | 6 | 1 | 25.7 | 0.5 |
14 | 10 | 6 | 2 | 24.3 | 1 |
15 | 10 | 2 | 2 | 24.2 | 0.94 |
16 | 10 | 6 | 2 | 24.3 | 0.9 |
17 | 7.5 | 4 | 2.5 | 17.2 | 1.5 |
18 | 7.5 | 8 | 2.5 | 17.5 | 1.32 |
19 | 12.5 | 8 | 1.5 | 31.5 | 0.9 |
20 | 12.5 | 4 | 1.5 | 31.9 | 0.5 |