Table 4 Detailed description of four-op-amp biquad high-pass filter fault modes.
Fault type | Fault mode | Nominal value | Tolerance range | Fault value |
---|---|---|---|---|
F00 | NF | – | – | – |
F01 | C1↓ | 5 nF | 10% | 3.5 nF |
F02 | C1↑ | 5 nF | 10% | 6.5 nF |
F03 | C2↓ | 5 nF | 10% | 3.5 nF |
F04 | C2↑ | 5 nF | 10% | 6.5 nF |
F05 | R1↓ | 6.2 kΩ | 5% | 4.3 kΩ |
F06 | R1↑ | 6.2 kΩ | 5% | 8.1 kΩ |
F07 | R2↓ | 6.2 kΩ | 5% | 4.3 kΩ |
F08 | R2↑ | 6.2 kΩ | 5% | 8.1 kΩ |
F09 | R3↓ | 6.2 kΩ | 5% | 4.3 kΩ |
F10 | R3↑ | 6.2 kΩ | 5% | 8.1 kΩ |
F11 | R4↓ | 1.6 kΩ | 5% | 1.1 kΩ |
F12 | R4↑ | 1.6 kΩ | 5% | 2.1 kΩ |