Table 5 Fuzzy rule base for the InC-FLC MPPT controller, using \(SInC\) and its rate of change (CSI) as input variables.

From: Hybrid fuzzy logic approach for enhanced MPPT control in PV systems

Fuzzy rules

\(SInC = \frac{{I_{{PV}} }}{{V_{{PV}} }} + \frac{{dI_{{PV}} }}{{dV_{{PV}} }}\)

NB

NM

NS

ZE

PS

PM

PB

\(CSI\)

NB

PB

PM

ZE

ZE

ZE

NM

NB

NS

PB

PM

PS

ZE

NS

NM

NB

ZE

PB

PM

PS

ZE

NM

NB

NB

PS

PB

PM

PS

ZE

NS

NM

NB

PB

PB

PM

ZE

ZE

ZE

NM

NB