Table 5 Fuzzy rule base for the InC-FLC MPPT controller, using \(SInC\) and its rate of change (CSI) as input variables.
From: Hybrid fuzzy logic approach for enhanced MPPT control in PV systems
Fuzzy rules | \(SInC = \frac{{I_{{PV}} }}{{V_{{PV}} }} + \frac{{dI_{{PV}} }}{{dV_{{PV}} }}\) | |||||||
---|---|---|---|---|---|---|---|---|
NB | NM | NS | ZE | PS | PM | PB | ||
\(CSI\) | NB | PB | PM | ZE | ZE | ZE | NM | NB |
NS | PB | PM | PS | ZE | NS | NM | NB | |
ZE | PB | PM | PS | ZE | NM | NB | NB | |
PS | PB | PM | PS | ZE | NS | NM | NB | |
PB | PB | PM | ZE | ZE | ZE | NM | NB |