Table 1 Physical properties of cement.

From: Impact of carbon nanotubes on chloride diffusion in cement mortar under temperature gradient conditions

Description

Requirements as per BS EN 197-1:2011

Typical results

Fineness: Blaine air permeability (m2/kg)

 

310–330

Specific gravity

 

3.13–3.14

Soundness: Le Chatelier exp., mm

≤ 10

0.10–0.15

% Standard consistency

 

26.0–28.0

Time of setting: Vicat test

 Initial, minutes

≥ 60

180–190

 Final, minutes

 

220–230

Compressive strength, MPa

 2 Days

≥ 10

22–26

 7 Days

 

38–42

 28 Days

≥ 42.5 ≤ 62.5

48–52