Table 15 FPR and FNR obtained based on different damage detection methods.

From: A novel damage detection method based on sequential iteration and Gaussian mixture model for structural health monitoring under environmental effects

 

Cointegration

PCA

GMM

Proposed GMM method

FPR

1.25%

1.61%

4.54%

0.60%

FNR

98.33%

99.81%

0%

0%