Basic Functional Areas | Formula |
|---|---|
Loading and Unloading Area | \(\:{S}_{1}=\frac{{Q}_{1}\text{*}{s}_{a}}{{T}_{1}\text{*}{p}_{a}}\:\) (1) |
Express Temporary Storage Area | \(\:{S}_{2}=\frac{{Q}_{2}\text{*}{v}_{b}}{{p}_{b}}+{S}_{b}\) (2) |
Primary Sorting Area | \(\:{p}_{c1}=\frac{{Q}_{3}}{{T}_{3}}\) (3) |
\(\:{S}_{3}=\frac{{Q}_{3}}{{p}_{c2}}\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\) (4) | |
Small Sorting Area | \(\:{S}_{6}={S}_{d1}+{S}_{d2}\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\) (5) |
\(\:{Q}_{e}={p}_{e1}-{p}_{e2}\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\:\) (6) | |
Comprehensive Office Area | \(\:{S}_{7}={U}_{f1}\text{*}{s}_{f1}+{U}_{f2}\text{*}{s}_{f2}\) (7) |
Security Inspection Area | \(\:{S}_{8}={U}_{g}\text{*}{s}_{g}+{S}_{g}\) (8) |
Packaging and Processing Area | \(\:{S}_{9}={U}_{h}\text{*}{s}_{h}\) (9) |
Storage Area | \(\:{S}_{10}=\frac{{Q}_{10}\text{*}{v}_{i}}{{p}_{i}}+{S}_{i}\) (10) |
Other Functional Areas | \(\:{S}_{11}={U}_{j}\text{*}{s}_{j}+{S}_{i}\) (11) |
\(\:{Q}_{1}\)represents the logistics volume of a single loading and unloading operation; \(\:{s}_{a}\)is the required area for a single loading and unloading platform; \(\:{T}_{1}\)is the specified time for a single loading and unloading operation; \(\:{p}_{a}\)is the loading and unloading efficiency of a single loading and unloading platform; \(\:{Q}_{2}\)represents the average storage volume of the temporary storage area per unit time; \(\:{v}_{b}\)denotes the space occupied by a unit storage volume; \(\:{p}_{b}\)is the storage space efficiency per unit area; \(\:{S}_{b}\)refers to the area required for other functional devices; \(\:{p}_{c1}\)represents processing efficiency per unit time; \(\:{\:Q}_{3}\)represents the logistics volume of the stage sorting operation; \(\:{T}_{3}\)represents the specified time for the stage sorting operation; \(\:{p}_{c2}\)represents the efficiency of parcel processing per unit area under the device selection scheme for achieving\(\:{p}_{c1}\); \(\:{S}_{d1}\)denotes the area of the sorting operation zone, calculated in a manner identical to that of the primary sorting zone; \(\:{S}_{d2}\)signifies the area of the unpacking zone, computed using the same method as for the parcel temporary storage zone; \(\:{p}_{e1}\)represents the efficiency of logistics input; \(\:{p}_{e2}\)represents the efficiency of sorting and supply; \(\:{U}_{f1}\)represents the average number of office personnel per unit time; \(\:{S}_{f1}\)is the per capita office space, typically taken as \(4.5\sim 7m^{2}\); \(\:{U}_{f2}\)denotes the number of information system devices; \(\:{S}_{f2}\)is the area occupied by each device, generally set at \(4.5\sim 5.5m^{2}\); \(\:{U}_{g}\)represents the number of security checkpoints; \(\:{s}_{g}\)is the area required per unit security checkpoint; \(\:{S}_{g}\)is the area of the emergency isolation zone; \(\:{Q}_{10}\)is the design storage capacity of the storage area; \(\:{v}_{i}\)is the space occupied by a unit of storage; \(\:{p}_{i}\)is the storage space efficiency per unit area; \(\:{S}_{i}\:\)is the area required for other functional equipment; \(\:{U}_{j}\)is the number of equipment (or personnel) required for the functional area; \(\:{s}_{j}\)is the area required per unit of equipment (or personnel); \(\:{\:s}_{i}\)is the area required for other functional equipment. | |