Table 3 Mean, standard deviation, and ANOVA P-value of retention values in newtons for frameworks across four study groups.

From: Evaluation of Non-dental open source software in comparison to dental software in construction of digitally designed partial dentures frameworks

Software Type

Mean

± SD

P-Value

F-Value

Blender group

6.61 N (a)

1.13

0.00001

49.37

Exocad group

10.77 N (b)

1.73

3Shape group

11.21 N (b)

0.07

Conventional group

8.94 N (c)

0.05

  
  1. * SD: Standard deviation, P; Probability level, Significant difference (P ≤ 0.05). Different letters reflect statistically significant differences in framework adaptation between groups.