Table 11 Comparison of FEA simulation results with experimental results.

From: Computational optimization of 3D printed bone scaffolds using orthogonal array-driven FEA and neural network modeling

Geometry Type

Wall Thickness

(mm)

Load

(kN)

Experimental

Displacement

(mm)

FEA Simulation

Error %

Lidinoid

1.0

3

2.84

3.08

8.45

Lidinoid

1.5

6

2.63

2.47

6.08

Lidinoid

2.0

9

2.42

2.12

12.39

Diamond

1.0

3

1.86

1.73

6.98

Diamond

1.5

6

1.12

1.21

8.03

Diamond

2.0

9

1.02

1.17

14.7

Gyroid

1.0

3

0.62

0.7

12.9

Gyroid

1.5

6

0.52

0.61

17.3

Gyroid

2.0

9

0.48

0.56

16.66