Table 3 Comparative analysis of the proposed algorithm versus FrTMs with (GSM, HM, and GRM) on the MIT-BIH arrhythmia in KLD and JSD.

From: Optimized bio-signal reconstruction and watermarking via enhanced fractional orthogonal moments

Signal

FrTM - GSM

FrTM - HM

FrTM - GRM

Proposed algorithm

KLD

JSD

KLD

JSD

KLD

JSD

KLD

JSD

Rec. 100

0.0872

0.0623

0.0531

0.0482

0.1103

0.0742

0.0392

0.0310

Rec. 104

0.2144

0.1073

0.0785

0.0613

0.5614

0.1712

0.0519

0.0427

Rec. 109

0.0712

0.0584

0.0327

0.0381

0.0760

0.0592

0.0051

0.0093

Rec. 115

0.0814

0.0637

0.0398

0.0417

0.0882

0.0682

0.0210

0.0214

Rec. 124

0.0364

0.0413

0.0592

0.0518

0.0602

0.0581

0.0087

0.0126

Rec. 202

0.0398

0.0429

0.0350

0.0396

0.0828

0.0648

0.0053

0.0086

Rec. 230

0.0474

0.0462

0.0342

0.0387

0.0572

0.0528

0.0078

0.0112

Average

0.0825

0.0603

0.0475

0.0456

0.1480

0.0784

0.0199

0.0195